MINMAX Technology
MAU01M-24
MAU01M-24
The MINMAX MAU01M series – an innovative range of 1W
medical-approved isolated DC-DC converters encapsulated in a SIP-7 package,
meticulously designed for medical applications. With 9 models available,
supporting input voltages of 5, 12, and 24VDC, and providing output voltages of
5, 12, and 15VDC, this series ensures versatility to meet various medical
device requirements.
The MAU01M series boasts an I/O isolation specified for 4000VAC with reinforced insulation, rated for a reliable 300Vrms working voltage. Additional features include short circuit protection, low I/O leakage current of 2μA max, and an operating ambient temperature range from -40℃ to 95℃ without derating. Aligning with the 4th edition medical EMC standard, the series holds medical safety approval with 2xMOPP (Means Of Patient Protection) per the 3.2 Edition of IEC/EN 60601-1 & ANSI/AAMI ES 60601-1.
Read More
The MAU01M series boasts an I/O isolation specified for 4000VAC with reinforced insulation, rated for a reliable 300Vrms working voltage. Additional features include short circuit protection, low I/O leakage current of 2μA max, and an operating ambient temperature range from -40℃ to 95℃ without derating. Aligning with the 4th edition medical EMC standard, the series holds medical safety approval with 2xMOPP (Means Of Patient Protection) per the 3.2 Edition of IEC/EN 60601-1 & ANSI/AAMI ES 60601-1.
If you are interested in our product, you can contact us through our contact page.
In order to use the wishlist please make sure you are registered as a user to proceed.
OK
SKU:
MAU01M-24
Product information "MAU01M-24"
The MINMAX MAU01M series – an innovative range of 1W
medical-approved isolated DC-DC converters encapsulated in a SIP-7 package,
meticulously designed for medical applications. With 9 models available,
supporting input voltages of 5, 12, and 24VDC, and providing output voltages of
5, 12, and 15VDC, this series ensures versatility to meet various medical
device requirements.
The MAU01M series boasts an I/O isolation specified for 4000VAC with reinforced insulation, rated for a reliable 300Vrms working voltage. Additional features include short circuit protection, low I/O leakage current of 2μA max, and an operating ambient temperature range from -40℃ to 95℃ without derating. Aligning with the 4th edition medical EMC standard, the series holds medical safety approval with 2xMOPP (Means Of Patient Protection) per the 3.2 Edition of IEC/EN 60601-1 & ANSI/AAMI ES 60601-1.
The MAU01M series boasts an I/O isolation specified for 4000VAC with reinforced insulation, rated for a reliable 300Vrms working voltage. Additional features include short circuit protection, low I/O leakage current of 2μA max, and an operating ambient temperature range from -40℃ to 95℃ without derating. Aligning with the 4th edition medical EMC standard, the series holds medical safety approval with 2xMOPP (Means Of Patient Protection) per the 3.2 Edition of IEC/EN 60601-1 & ANSI/AAMI ES 60601-1.
Industry: | Medical Safety |
---|---|
Input Voltage: | 24V |
Operating Temp Range: | -40 to +95 degC |
Output Power: | 1W |
Output Voltage: | 5, 12, 15V |
Package: | SIP-7 |
Power Type: | DC-DC |
